Sitemap

Laurel Electronics provides digital panel meters / controllers, totalizers, counters, loop-powered meters, temperature meters, for all types of transducers or process indication & control.

 

 




Digital Controller

Laureate™ Digital Panel Meters,Counters & Remote Displays

For demanding industrial measurement & control applications

Modular construction

Setpoint control outputs

High speed with 99.99% accuracy
(60 readings / second for DPMs)
Linearized transmitter outputs
All ranges precalibrated Serial data or BCD communications
Advanced programmable features Highly cost-effective
Compact 1/8 DIN package Shipped ready to run
Front panel sealed to NEMA-4

Datalogging software

Functions Offered by Laureate Products

Digital Panel Meters

Programmable Counters

DC Volts, mV Potentiometer Follower Frequency, Rate, Period Pulse Input Batch Controller
DC Amps & mA Thermocouples & RTDs Time Interval, Stopwatch A+B, A-B, A*B, A/B, A/B-1 Draw
Microvolts, Microamps Load cell, 4- and 6-wire Phase Angle, Duty Cycle PC-based datalogging
True AC RMS Volts & mV Weight / scale meter Voltage-to-Frequency Converter:  
Process Signal Custom curve linearization Quadrature Position & Rate  
Strain Gage PC-based datalogging Up / down Totalizer  

Remote Displays

6 digit LED display, -999999 to +999999. Accepts RS-232 or RS-485 input from panel meter, counter, or other external source.
Up to 31 units addressable on one serial data line. Optional dual-relay control output tied to display.
Optional isolated 0-10 V or 4-20 mA transmitter output tied to display. ---------
Standard Features of Laureate Panel Meters & Counters Options for Laureate Panel Meters & Counters
Simple setup via pushbuttons or setup via computer. Dual setpoint relays: 10 A mechanical relays or opto-isolated solid state relays for control and alarm.
Multifunction, high-resolution instrument at single-function price.
High read rate for fast control response and true peak value display. Analog output: 0-20 mA plus 10 Vdc, isolated, linearized and scaled to display.
Adaptive filter eliminates noise, yet responds rapidly to changes in signal level.
Auto-tare for weighing applications. Serial I/O: isolated RS-232 or multipoint RS-485.
Isolated 5, 10 and 24 Vdc excitation eliminates need for external supply. BCD output: isolated, parallel, stored, 3-state.
Wide-range 85-264 Vac input power for global use. Low voltage power: for 8-28 Vac or 9-37 Vdc operation off battery power.
1/8 DIN case for easy replacement of existing meters.
Plug-in screw terminals for power and signal included Datalogging software: Up to 31 instruments on one data line to a PC, plus 33 virtual meters to display arithmetic combinations of meter readings.
Sealed to NEMA-4X (IP-65) when panel mounted for high-pressure washdown
Designed to meet international safety standards. --
Certified for safety per UL 3101-1 and CAN/CSA-C22.2 No 1010.1-92. --
Certified for EM compatibility per EN 61010-1:1993 (CE Mark). --

LAUREATE™ Series Hardware Overview

Modular Hardware

The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. The base configuration for a panel meter or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board.

Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a fully-loaded Laureate.Digital Interface Boards


Digital Interface Boards
Click on each board to identify the board function!

Main Module

The main module (with computer and display boards) defines the Laureate series (DPM, weight meter, counter, or remote display), version (standard or extended), and LED display color (red or green). The number of digits is 5 for DPMs or 6 for counters, weight meters and remote displays. Digits are a full 14.2 mm (0.56") high.
Power Supply Boards

The same standard switching power supply board handles inputs of 85-264 Vac for worldwide AC use, plus 90-370 Vdc. An optional low voltage power supply board handles 8-28 Vac and 9-37 Vdc, allowing the meter to be powered by batteries. Isolated 5, 10 or 24 Vdc transducer excitation output is standard with either supply.

Signal Conditioner Boards

Four input boards are used for DPMs:

  • DC (volts, amps, mV, mA, process such as 4-20 mA, strain, pot follower).
  • Temperature (J, K, T, E, N, R, S thermocouple, Pt 100 ohm RTD).
  • True RMS (AC volts, mV, amps, mA).
  • Load cell (load cells, scale meter, strain gauges, microvolts).

Three input boards are used for counters: dual-channel counter, voltage-to-frequency, and quadrature. Click on each link below to be linked to the appropriate page.

Setpoint Controller Boards

Two isolated setpoint controller options are available to add control and alarm capability to DPMs, counters and remote displays:

Analog Output Board

An optional isolated analog output board is available to provide 0-10 Vdc and 4-20 mA outputs for DPMs, counters and remote displays. It is ideal to drive a chart recorder or for transmission to a control room. The two outputs are linearized and independently scaled to the display. In the pulse input batch controller, a 10A relays fill the socket of the analog output board.

Digital Interface Boards

Optional isolated interface boards allow the Laureate to communicate with a computer or PLC. The two serial boards allow the Laureate to drive a remote display, or to serve as a remote display.

Designed for Industrial Use
All Laureates are housed in a compact and rugged 1/8 DIN case which fits in a standard 45 x 92 mm panel cutout and requires only 102 mm (4.0") behind the panel (plus connectors). In many applications, a Laureate can replace a larger, more expensive instrument. The Laureate case is sealed to NEMA-4X (IP-65) requirements from the front when panel mounted to allow high-pressure washdown.


Connectors Included
All power and signal connections are via UL / IEC / CSA rated screw-clamp terminals, which are standard. The RS-232 and RS-485 options are connected via an RJ-11 phone jack. The BCD option uses a 30-pin, 0.1" mass termination ribbon cable connector
Easy Setup & Calibration

All Laureate meters and counters are shipped fully configured, calibrated, and ready to run. All ranges of Laureate DC, AC and temperature meters are calibrated at the factory, with calibration factors stored in EEPROM. This allows different ranges to be selected via plug-in jumpers, with no need to recalibrate the meter for each new range.

Setup can be from the front panel or by using powerful and easy-to-use Laureate Setup & Calibration Software, which can be downloaded at no charge. It can simplify setup whether the PC is connected to the instrument or not. Absolute calibration of Laureate panel meters requires temporary connection to an external calibrator and to a PC running Laureate Setup & Calibration Software. System-level scale and offset calibration can also be from the front panel to produce specified readings from known signals, such as 4-20 mA = 0.00% to 100.00%.

Laureate Datalogging Software
Datalogging Software turns a PC connected to up to 31 Laureate instruments into a powerful, low-cost datalogging system. The Laureates can be any mix of digital panel meters and counters, excluding only remote displays. Data can be displayed on a computer screen in the form of up to 64 simulated panel meters, which can include virtual meters that show an arithmetic combination of meter readings or totalized readings, such as volume from flow rate. Data is can be captured on disk in the form of comma-delimited ASCII files for analysis and graphic by an external program such as MS Excel.

Back To Previous Page Top of The Page Take Me Home Send Us A Message Join Our Email List Datatools - On Line Reference Resources
This Day In History
Site Search  

FLW, Inc - 3505 Cadillac Ave - Bldg E - Costa Mesa, CA. - 92626 - USA  - Ph (714) 751 - 7512  - Fax (714) 751 - 0213
 
FLW, Inc 1997- - S.D.G.