Sitemap

Laurel Electronics provides digital panel meters / controllers, totalizers, counters, loop-powered meters, temperature meters, for all types of transducers or process indication & control.

 

 

 

 

       

Programmable DIN-rail Modbus transmitters for DC voltage & current, AC RMS voltage & current, process (e.g., 4-20 mA), strain, potentiometer follower, load cell, microvolt, and temperature (thermocouple & RTD). Includes plug-in screw clamp connectors and RS-232 / RS-485 port for programming.

To configure and price out an instrument, select Quantity, press on the radio buttons below, then on "Add items to shopping cart." If you wish to construct a model number so that your company can issue a purchase order, combine the radio button selections to create a model number in this format: TM202DCV1. This is for a 4-20 mA output transmitter, standard main board, 95-240 Vac power, isolated dual solid state relays, and a ±200.00 mV input signal. Includes detachable screw clamp connectors.
  Laureate Modbus Transmitter
Transmiter Type:
TM Laureate Modbus Transmitter.

$195.50

Main Board:
2 Standard Main Board NC
4 Extended Main Board $38.00
Power:
0 Isolated 95-240 Vac & 95-300 Vdc NC
1 Isolated 10-34 Vac & 10-48 Vdc. $28.50
Setpoint Output:
0 None. NC
2 Isolated Dual Solid State Relays. $28.50
Scalable Analog Output:
0 None. NC
1 4-20 mA or 0-10V analog output. $23.75
Signal Input:

 

DC Volts
DCV1 ±200.00 mV

NC

 

DCV2 ±2.0000 V.
DCV3 ±20.000 V.
DCV4 ±200.00 V.
DCV5 ±600.0 V.
DC Amps
DCA1 ±2.0000 mA.

NC

DCA2 ±20.000 mA.
DCA3 ±200.00 mA.
DCA4 ±5.000 A.
Process Signals (e.g., 4-20 mA, 0-5 V)
P Default Scaling. 4-20 mA = 0-100.00. NC
P1 Custom Scaling $9.50
In the write-in field of your invoice, specify min input, min reading; max input, max reading.
Strain Gage, Potentiometer (4-wire ratio)
SG Default Scaling. 0-200 mV = 0-100.00. NC
SG1 Custom Scaling. $9.50
In the write-in field of your invoice, specify min input, min reading; max input, max reading.
True AC RMS Volts
RMV1 200.00 mV

$33.25

RMV2 2.0000 V
RMV3 20.000 V
RMV4 200.00 V
RMV5 600.0 V
True AC RMS Amps
RMA1 2.0000 mA

$33.25

RMA2 20.000 mA
RMA3 200.00 mA
RMA4 5.000 A
Note: The same AC RMS signal conditioner can be user configured for AC Volts or AC Amps. It is precalibrated in EEPROM for all AC Volt and AC Amp ranges listed
Thermocouples
JC Thermocouple Type J, -210°C to 760°C NC
JF Thermocouple Type J, -347°F to 1400°F
KC Thermocouple Type K, -347°C to 1372°C
KF Thermocouple Type K, -408°F to 2501°F
TC Thermocouple Type T, -257°C to 400°C
TF Thermocouple Type T, -430°F to 752°F
EC Thermocouple Type E, -240°C to 1000°C
EF Thermocouple Type E, -400°F to 1830°F
NC Thermocouple Type N, -240°C to 1000°C
NF Thermocouple Type N, -410°F to 2370°F
SC Thermocouple Type S, -46°C to 1768°C
SF Thermocouple Type S, -51°F to 3214°F
RC Thermocouple Type R, -45°C to 1768°C
RF Thermocouple Type R, -49°F to 3213°F
RTDs (100 Ohm Platinum)
P385C RTD Alpha .00385, -202°C to 850°C NC
P385F RTD Alpha .00385, -331°F to 1562°F
P392C RTD Alpha .003925, -202°C to 631°C
P392F RTD Alpha .003925, -331°F to 1168°F
Note: The same temperature signal conditioner board can be user configured for all thermocouple and RTD types listed. Temperatures for each type are spanned by a single range.
Load Cells (6-wire ratio)
WM Default Scaling. 0-20 mV in = 4-20 mA out

$52.25

WM1 Custom Scaling
In the write-in field of your invoice, specify min input, min reading; max input, max reading. Full-scale input is 20-500 mV. 5V or 10V DC excitation for two 350-ohm load cells in parallel.
Accessories:
CBL03 RS-232 cable, TM to computer $18.05
Unselected
CBL02 USB to RS-232 cable adapter $37.05
Unselected


Back To Previous Page Top of The Page Take Me Home Send Us A Message Join Our Email List Datatools - On Line Reference Resources
This Day In History
Site Search  

FLW, Inc - 3505 Cadillac Ave - Bldg E - Costa Mesa, CA. - 92626 - USA  - Ph (714) 751 - 7512  - Fax (714) 751 - 0213
 
FLW, Inc 1997- - S.D.G.