Hydraulic Driven Gas Booster
HG Series

Haskel HG Series

Depending on the application, the Haskel basic booster is supplied as a single-stage/double-acting or two-stage design for integration by the customer. Both designs feature:

  • Single-acting, single-stage air pressure amplifiers
  • 3 models with ratios of (2.5:1), (3.5:1) & (4.5:1)
  • Maximum inlet pressure of 125 psi
  • Maximum outlet pressures from 320 psi to 600 psi

Single-Stage/Double-Acting Gas Booster Units

  • Available in 9 models with flow rates to 160 scfm and maximum supply and outlet pressures to 20,000 psi
  • Designed for high flow and low-to-medium compression ratios
  • Multiple units can be driven by one power source
  • Accepts full available supply pressure

Two-Stage Gas Booster Units

  • Available in 9 models with flow rates to 29 scfm, maximum supply pressure to 9,000 psi, and maximum outlet pressure to 20,000 psi
  • Designed for low flow and medium-to-high compression ratios
  • Modular construction for easy gas section maintenance
  • Adapts readily to multiple units in parallel or in series driven by one power source

Gas booster compressors are suitable for transfer and pressurization of:

  • Nitrogen (N2)
  • Helium (He)
  • Breathing Air (N2O2)
  • Nitrous Oxide (N2O)
  • Carbon Dioxide (CO2)
  • Neon (Ne)
  • Argon (Ar)
  • Sulphur Hexafluoride (SF6)
  • Oxygen (O2)
  • Carbon Monoxide (CO)
  • Hydrogen (H2)
  • Methane (CH4)
  • Ethylene (C2H4)
  • Deuterium (D2)
  • Natural Gas (CH4)
Model Supply Pressure Min. (PSIG) Supply Pressure Max. (PSIG) Outlet Pressure Max. (PSIG) Max. CR (rec) Piston Displacement Per Cycle (In.3) Max Cycles Per Minute
100HGD6-50100900013500640.125
100HGD6-85100600065006107.425
100HGD6-11550275027506190.925
100HGD6-14550185018506311.625
Model Supply Pressure Min. (PSIG) Supply Pressure Max. (PSIG) Outlet Pressure Max. (PSIG) Max. CR (rec) Piston Displacement Per Cycle (In.3) Max Cycles Per Minute
100HGT6-115/50502750135001719525
100HGT6-115/855027506500649525
100HGT6-85/50100600013500965325
100HGT6-145/50501850650028015625
100HGT6-145/85501850650010415625
120HGD10-50100900013500667.818
120HGD10-85100600065006178.918
120HGD10-16550185018506715.718
120HGT10-85/50100600013500963418
120HGT10-165/85501850650014435818
120HGT10-165/5050185013500963418
Haskel Liquid Pump

We're happy to help.

We can help size an amplifier, rebuild a pump, or engineer a custom pressure system.