RKC INSTRUMENT : REX Century Series Controllersquotation

The REX century series is high performance PID controller with easy-to-use.Heat/cool control and two alarms including heater break alarm and loop break alarm are available.The REX Century series is available in five DIN sizes from 1/16 DIN to 1/4 DlN.

Digital Temperature Controller -REX D100 Series
REX-D100:
REX-D100 241.00
1:Control Action:
F: PID Autotune 00.00
W: PID Autotune 72.00
2:Control Output(Heat):
M: Relay Contact 00.00
V: Voltage Pulse 00.00
[ ]: Specify Signal Code 38.00
T: Triac 38.00
3:Control Output(Cool):
N: None(Control Action F) 00.00
M: Relay Contact 00.00
V: Voltage Pulse 00.00
[ ]: Specify Signal Code 36.00
T: Triac 36.00
4:Alarms:
N:None 00.00
D: Dual Alarms (Field Programmable) 38.00
5:Heater Break Alarms:
N: None 00.00
S: Single Phase(specify 30A or 100A CTL-not included) 29.00
D:3-Phase(specify two 30A or 100A CTLs-not included) 29.00
6:Contact output:
N:None 00.00
1: Supplied-SP1/SP2 selection, standard 29.00
1: Supplied- Run/Stop selection, specify Z-188 at the end of model code 29.00
7:Retransmission:
N:None 00.00
[ ]: specify signal code 68.00
8:Communication:
N:None 00.00
5: RS-485 68.00
9:NEMA 4X:
N:None 00.00
1:Supplied 15.00
Accessories:
N:None 00.00
CTL-6-P-N 32.00
CTL-6-P-H 21.00
CTL-12-S56-10L-N 46.00
CTL-12-S56-10L 36.00
Shunt Resistor:
N: None 00.00
PTF6S 12.00
   
Configured model number: D100 F M N N N N N N N N N
Configured price : $626.00*
Ordering INSTRUCTIONS-:
1. If Heat/Cool PID Control with AT is selected, contact Input, Analog Retransmission Output, 3 Phase HBA and Communication Function can not be selected.

2. When Dual Alarms and HBA are specified, HBA is assigned to Alarm Relay #2

3. Select 1 from the following: Contact Input, Analog Retransmission, 3 Phase HBA or Communication Function.

4. If continuous voltage/Current output is specified, HBA can not be selected.

5. For 3 Phase HBA, Both CTL'S must have the amperage.

6. A Shunt register is required when used for current Input (Soled Spectrally)

7. Triace Rated to 0.5A@40 oC. Does not confirm to any UL, CSA listing.

SIGNAL CODE FOR D100 SERIES
CODE VOLTAGE
4 0 TO 5 VDC
5 0 TO 10 VDC
6 1TO 5 VDC
CODE CURRENT
7 0 TO 20 mADC
8 4 TO 20 mADC

 

Our process and temperature control technology is widely used in industry.

callCall - (800) 576- 6308 or Mail for assistance
create facebook
5672 Bolsa Avenue Huntington Beach, CA 92649 - USA - Ph (714) 622-2000 - Fax (714) 622-2001
- © FLW, Inc 1997- - S.D.G.